INTRODUCTION TO THE DRIVE

49’1340 e

FlexPak 3000

2-15

.JOG

---------

Active only when in KEYPAD control mode. This key causes the drive reference

to ramp up at the JOG ACCEL/DECEL rate to jog speed. When this key is

released, the drive reference ramps to zero at the same rate. If the drive status
indicators show that the drive is "not ready", this request will be ignored.

RUN

Active only when in KEYPAD control mode. This key allows the motor to

accelerate to the speed reference setpoint.

STOP

------

RESET

#

STOP is active at all times regardless of the CONTROL SOURCE SELECT
setting. Pressing the key with the drive running causes the drive to stop in the
selected stop mode. RESET is active only if the drive is not running and
CONTROL SOURCE SELECT is set to KEYPAD. When the RESET key is
pressed, drive faults and alarms will be reset (see section 7 for more

information.)