PULSE TACH FEEDBACK (P.292)

The digital value from the pulse tachometer after all hardware and software scaling.
For use with pulse tachometer feedback only.

OIM Menu Path(s):

Speed/Voltage Loop (SPD) - Speed/Voltage Loop (SPD) Test Points

PULSE TACHOMETER KIT (P.798)

Indicates the presence of a pulse tach kit.

OIM Menu Path(s):

Drive Information

REGULATOR SW VERSION (P.794)

Indicates the regulator software version.

OIM Menu Path(s):

Drive Information

SPD LOOP ERROR (P.297)

The speed loop error signal, which represents the difference between the SPD LOOP REFERENCE and
the SPD LOOP FEEDBACK signals.

OIM Menu Path(s):

SPD - Speed/Voltage Loop (SPD) Test Points

SPD LOOP FEEDBACK (P.296)

An output that represents the selected speed/voltage loop drive feedback value after all scaling.

OIM Menu Path(s):

SPD - Speed/Voltage Loop (SPD) Test Points

SPD LOOP LAG OUTPUT (P.298)

An output representing the value immediately after the Speed Loop Lag function.

OIM Menu Path(s):

SPD - Speed/Voltage Loop (SPD) Test Points

SPD LOOP OUTPUT (P.299)

Speed Loop PI function output value to the CML.

OIM Menu Path(s):

SPD - Speed/Voltage Loop (SPD) Test Points
Current Minor Loop (CML) - CML Test Points

SPD LOOP REFERENCE (P.295)

An output that represents the reference value to be used by the speed loop regulator in the drive.

OIM Menu Path(s):

SPD - Speed/Voltage Loop (SPD) Test Points,
Drive Reference - Drive Reference Test Points

SPD SOURCE SELECT OUT (P.193)

The user selected speed reference source value. It is an input to the speed reference ramp section.

OIM Menu Path(s):

Drive Reference - Drive Reference Test Points