NetEngine IAD User Guide

WAN Configuration

94

Adding a DLCI

To add a DLCI:

1. On the Frame Relay DLCI Configuration menu, type

1

to select Add

New DLCI.

2. The IAD displays the following prompt:

Enter dlci number:

Type a DLCI value between 16 and 1023 (default is 32 for data and 33
for voice) and press Enter.

3. The IAD displays the FR Encapsulation Configuration menu:

Figure 4–57. Frame Relay Encapsulation Configuration Menu

Type the option corresponding to the encapsulation method you intend
to use.

4. The IAD displays the FR DLCI Options menu:

Figure 4–58. Frame Relay DLCI Options Menu

Configuring Transmit CIR

To set up Configure Transmit CIR, type

1

to select Configure Transmit

CIR.

5. The IAD displays the Bc prompt:

Enter the committed burst size (Bc) in number of
bits (0):

Type the committed burst size.

*****************************************

FR Encapsulation Configuration

*****************************************

Current Encapsulation: None

1. RAW (No Encapsulation)
2. Proprietary Voice DLCI
3. RFC 1490
4. ATM RFC 1483 (Tunneling)

*****************************************

FR DLCI Options

*****************************************

Current Encapsulation: None

1. Configure Transmit CIR
2. Configure Receive CIR
3. Configure FRF.12 Fragmentation

NOTE

To continue without configuring CIR or FRF.12
Fragmentation, press Escape. CIR is not required for bull
bandwidth circuits.