Figure 4–64. frame relay maintenance protocol menu, Configuring the congestion parameters – Verilink Net Engine (3150-30626-001) Product Manual User Manual

Page 119

Advertising
background image

NetEngine IAD User Guide

WAN Configuration

100

Figure 4–64. Frame Relay Maintenance Protocol Menu

4. Type the number that corresponds to the protocol on your network and

press Enter.

5. Reset the IAD (page

15

) for changes to take effect.

Configuring the Congestion Parameters

To configure the congestion parameters:

1. On the WAN Configuration menu.
2. Select Configure FR Options to display the Frame Relay Options menu

(page

97

).

3. Select Configure Congestion Parameters to display the FR Congestion

Configuration menu.

Figure 4–65. Frame Relay Congestion Configuration Menu

4. Do one of the following.

A. Select Configure Transmit Congestion Parameters and then follow
the on-screen messages to set:

u

FECN/BECN condition set size

u

FECN/BECN condition clear size

u

FECN/BECN max number of bytes to store

—or—
B. Select Configure Receive Congestion Parameters and then follow
the on-screen messages to:

u

FECN/BECN condition set size

u

FECN/BECN condition clear size

u

FECN/BECN max number of bytes to store

5. Reset the IAD (page

15

) for changes to take effect.

*****************************************

Frame Relay Maintenance Protocol

*****************************************

0. None
1. CCITT Q.933 Annex A Network
2. CCITT Q.933 Annex A User
3. CCITT Q.933 Annex A Both
4. ANSI T1.617 Annex D Network
5. ANSI T1.617 Annex D User
6. ANSI T1.617 Annex D Both
7. LMI Network (FRF.1.1)
8. LMI User (FRF.1.1)
9. LMI Both (FRF.1.1)

*****************************************

*

FR Congestion Configuration

*

*****************************************

1. Configure Transmit Congestion Parameters
2. Configure Receive Congestion Parameters