NetEngine IAD User Guide

Voice Path Configuration

162

settings is a message indicating the IAD will be configured for the
selected gateway after reset.

3. Reset the IAD (page

15

) when you finish voice path configuration.

Manual Configuration

Type

C

to display the AAL2/LES Manual Configuration menu (current

settings eliminated from this example):

Figure 7–23. AAL2/LES Manual Configuration Menu

Type the option for the command to execute and proceed to the
appropriate section.

Enabling and Disabling Ports

1. Type

P

to enable and disable ports.

2. The IAD displays the port control prompt:

Port Control x(10011001):

Enter a zero (0) in each port location to disable the port; enter a 1 in
each port location to enable the port. Press Enter to complete the step.

3. The IAD displays the AAL2/LES Manual Configuration menu.
4. Reset the IAD (page

15

) when you finish voice path configuration.

Setting the CAS Refresh Rate

1. Type

R

to set the CAS refresh rate.

2. The IAD displays this prompt:

New CAS refreshing rate in seconds (0 to DISABLE):

Enter a zero (0) to disable CAS refresh, or enable CAS refresh by
entering a non-zero refresh rate value.

3. The IAD displays the AAL2/LES Manual Configuration menu.
4. You must reset the IAD (page

15

) before enabling Idle CAS refresh.

Enabling and Disabling Idle CAS Refreshing

1. Type

I

to enable or disable idle CAS refreshing. You can only enable

idle CAS refresh when CAS refresh is enabled (immediately
preceding).

2. Type

E

to enable Idle CAS refresh, or

D

to disable Idle CAS refresh.

3. The IAD displays the AAL2/LES Manual Configuration menu, and

indicates in the message section that the change in the Idle CAS
refresh will take place when the IAD is reset.

************************************

AAL2/LES Manual Configuration

************************************

P. Enable/Disable Ports
R. Set CAS refreshing rate
I. Enable/Disable idle CAS refreshing
S. Change Max. CPS-SDU Size; 45/64 Octets
T. Set "Combine Use" Timer
U. Enable/Disable User State Control
D. Enable/Disable Dialed Digit
A. Manual ATM Pace Control