NetEngine IAD User Guide

Administration

29

Setting Up
SNMP

You can enable SNMP over IP and/or EOC (when the voice gateway is
AAL2/LES CAS or ELCP). By default, the IAD is configured with SNMP
disabled. When SNMP is enabled and the settings are configured, you can
use SNMP to remotely manage the IAD by getting and setting IAD values,
and monitoring IAD events.

The IAD supports the following SNMP settings:

u

System Contact

u

System Name

u

System Location

u

SNMP Community

u

SNMP Trap Host IP Address

u

af-vmoa-0172 (AAL2/LES)

The following SNMP traps are supported:

u

System reset

u

Attempts to access SNMP with an invalid community name

u

Starting and stopping TFTP within SNMP

The IAD supports MIBs for RFCs 1213, 1317, 1406, 1493, 1463 as well as
af-vmoa-0172 (AAL2/LES MIB).

Using the SNMP Configuration Menu

To display the SNMP Configuration menu, type

7

on the Main menu. The

following SNMP tasks are accessed from this menu:

Figure 3–2. SNMP Configuration Menu

When you are done updating SNMP settings, you must reset the IAD for
the new settings to take effect.

*****************************************

SNMP Configuration Menu

*****************************************

E. Enable/Disable SNMP via IP
F. Enable/Disable SNMP via EOC
A. Enable SNMP via both IP and EOC
B. Disable SNMP via both IP and EOC
P. Configure System Contact
N. Configure System Name
L. Configure System Location
C. Configure SNMP Community
T. Configure SNMP Trap Host IP Address
U. Enable/Disable SNMP Traps via EOC
D. Configure Restart Trap Max Delay

NOTE

The strings you enter in SNMP are not case sensitive.