Verilink Net Engine (3150-30626-001) Product Manual User Manual

Page 287

Advertising
background image

NetEngine IAD User Guide

Troubleshooting and Diagnostics

268

Cannot receive or send
data

Incorrect PVC/DLCI
set for data channel

Verify these settings:
VPI: 0 to 255
VCI: 0 to 65535
DLCI: 16 to 1023
(default PVC 0/38; DLCI
32)
View Interface
(page

215

) and Media

statistics (page

226

) to

check the pack receive
and send status.

Incorrect network
setup

Check and correct
network setup as
necessary.

If IAD is configured as
router:

Incorrect or missing
LAN or WAN IP
address

Ensure that both the LAN
and WAN IP addresses
are configured.

Incorrect or missing
default static route

Review the routing table
and correct as necessary
(page

238

).

Incompatible RIPv1 Check and correct subnet

masks (255.255.255.0)
Update RIPv1 to RIPv2.

If the IAD is configured
as a bridge:

incorrect bridging
parameters

Review IAD configuration
(page

203

) and current

bridge status (page

239

).

Correct as necessary

Incorrect
connection

Ensure that the IAD is
connected to another
bridge

Missing peer or
converter

Install a converter to
convert 1483 cells to
Ethernet packets.

Table 14–1.Troubleshooting—Symptoms and Causes

Symptom

Probable Cause

Corrective Action

Advertising