Setting idle voltage mode, Figure 7–8. ground start oht mode selection menu – Verilink Net Engine (3150-30626-001) Product Manual User Manual

Page 165

Advertising
background image

NetEngine IAD User Guide

Voice Path Configuration

146

Setting Idle
Voltage
Mode

To set idle high voltage for loop start lines (POTS only), type

L

to display

the Loop Start Idle Voltage Selection menu:

Figure 7–8. Ground Start OHT Mode Selection Menu

Type the option for the task to perform. Proceed to the appropriate section.

Enabling and DIsabling Idle High Voltage Globally

1. Type

1

to enable or disable idle high voltage for all ports.

2. The IAD displays the following prompt:

Enter E to Enable, D to Disable:

Type

E

to enable idle high voltage for all ports, or

D

to disable it.

3. The IAD saves the mode you’ve selected and displays the menu.
4. Press Escape to return to the Voice Configuration menu and continue

with other voice path configuration.

Displaying Idle High Voltage Settings

Type

2

to display the idle high voltage setting on each port.

The IAD displays the following report:

1

Low Voltage

2

Low Voltage

3

Low Voltage

4

Low Voltage

Press any key to return to the Loop Start Idle Voltage Selection menu.

Enabling and DIsabling Idle High Voltage for a Specific Port

1. Type

3

to enable or disable idle high voltage for a specific port.

2. The IAD displays the port prompt:

Select Line: [1-8]

Type the port number to set.

3. The IAD displays the following prompt:

Enter E to Enable, D to Disable:

Type

E

to enable idle high voltage, or

D

to disable it.

4. The IAD saves the mode you’ve selected and displays the menu.
5. Press Escape to display the Voice Configuration menu and continue

with other voice path configuration.

Reset the IAD

Reset the IAD (page

15

) when you finish voice path configuration.

*******************************************

Loop Start Idle Voltage Selection

*******************************************

1. Enable/Disable Loop Start Idle High Voltage for all ports
2. Display current Loop Start Idle High Voltage settings
3. Enable/Disable Loop Start Idle High Voltage Setting per port

Advertising