Chapter 2 hardware installation, 1 installation notice, 1 environmental requirements – Amer Networks SS2R48G4i V2 User Manual

Page 19: 1 dust and particles

Advertising
background image

SS2R24G4i/SS2R48G4i

8

Chapter 2 Hardware Installation

2.1 Installation Notice

To ensure the proper operation of SS2R24/48G4i switch and your physical security, please read

carefully the following installation guide.

2.1.1 Environmental Requirements

„

The switch must be installed in a clean area. Otherwise, the switch may be damaged by

electrostatic adherence.

„

Maintain the temperature within 0 to 50 °C and the humidity within 5% to 95%, non-condensing.

„

The switch must be put in a dry and cool place. Leave sufficient spacing around the switch for good

air circulation.

„

The switch must work in the right range of power input AC power 100 ~ 240VAC (50 ~ 60Hz).

„

The switch must be well grounded in order to avoid ESD damage and physical injury of people.

„

The switch should avoid sunlight perpendicular incidence. Keep the switch away from heat sources

and strong electromagnetic interference sources.

„

The switch must be mounted to a standard 19’’ rack or placed on a clean level desktop.

2.1.1.1 Dust and Particles

Dust is harmful to the safe operation of SS2R24/48G4i switch. Dust can lead to electrostatic

adherence, especially likely under low relative humidity, causing poor contact of metal connectors or
contacts. Electrostatic adherence will result in not only reduced product lifespan, but also increased
chance of communication failures. The recommended value for dust content and particle diameter in
the site is shown below

Max Diameter (µm)

0.5 1 3 5

Max Density

(particles/m³)

1.4×10

7

7×10

5

2.4×10

5

1.3×10

5

Table 2-1 Environmental Requirements Dust

In addition, salt, acid and sulfide in the air are also harmful to the switch. Such harmful gases will
aggravate metal corrosion and the aging of some parts. The site should avoid harmful gases, such as
SO

2

, H

2

S, NO

2

, NH

3

and Cl

2

, etc. The table below details the threshold value.

Gas

Average (mg/m³)

Max (mg/m³)

SO

2

0.2 1.5

H

2

S

0.006 0.03

NO

2

0.04 0.15

Advertising