Yaskawa DriveWizard AC Drive User Manual

Page 141

Advertising
background image

P5

Par.

P5 Parameter Name

Conversion

E7/P7

Par.

E7/P7 Parameter

Name

n033

Motor OL Select

If n033 > 1, then L1-01 = 1

L1-01

Mtr OL Protect Select

n034

OH1 Stop Method

None

L8-03

OH Pre-Alarm Op Sel.

n035

Terminal S2 Select

If n035 >1, then table 4, else
H1-03 = 0Fh

H1-01

Terminal S3 Select

n036

Terminal S3 Select

Table 4

H1-02

Terminal S4 Select

n037

Terminal S4 Select

Table 4

H1-03

Terminal S5 Select

n038

Terminal S5 Select

Table 4

H1-04

Terminal S5 Select

n039

Terminal S6 Select

Table 4

H1-05

Terminal S5 Select

n040

Terminal MA Select

Table 5

H2-01

Terminal M1-M2 Sel.

n041

Terminal M1 Select

Table 5

H2-02

Terminal M3-M4 Sel.

n042

Master Analog Input
Sel.

NOT CONVERTED

NA

NA

n043

Terminal FI Select

If n043 =1, then H3-08 =2,
else H3-08 = 0

H3-08

Terminal A2 Signal
Level Select

n044

Freq Ref Retention

D

NOT CONVERTE

NA

NA

n045

Ref Loss Detect

oss Det Sel

None

L4-05

Freq Ref L

n046

Freq Ref Gain

n046*10 = H3-02

H3-02

Terminal A1 Gain

n047

Freq Ref Bias

n047*10 = H3-03

H3-03

Terminal A1 Bias

n048

Terminal AM Sel

Table 6

H4-01

Terminal FM Select

n049

Terminal AM Gain

n049*10 = H4-02

H4-02

Terminal FM Gain

n050

Carrier Freq select

NOT CONVERTED

NA

NA

n051

Pwr Loss Ride Thru sel

None

L2-01

Pwr Loss Det Select

n052

Spd Srch Current

None

b3-02

Spd srch Deact Current

n053

Min Baseblock Time

If n053 > 5.0 then L2-03 =
5.0, else n053 = L2-03

L2-03

Pwr Loss Min Base
Block Time

n054

Spd Search V/F

NOT CONVERTED

NA

NA

n055

Ride Thru Time None

L2-02

Pwr Loss Ride-Thru

Pwr Loss

Time

n056

Number of Restarts

None

L5-01

f Restart attempts

No.o

n057

Restart Select

If n057 = 1 then L5-02 = 0,
else L5-02 = 1

L5-02

Auto Restart Operation
Select

n058

Jump Freq 1

If n058 > 200.0, then d3-01
= 200.0, else n058 = d3-01

d3-01

Jump Frequency 1

n059

Jump Freq 2

If n059 > 200.0, then d3-02
= 200.0, else n059 = d3-02

d3-02

Jump Frequency 2

n060

Jump Bandwidth

If n060 > 20.0, then d3-04 =
20.0, else n064 = d3-04

d3-04

Jump Frequency Width

n061

Elapsed Timer Select

None

o2-08

Cum. Op Time Select

n062

Elapsed Time 1

NOT CONVERTED

NA

NA

n063

Elapsed Time 2

NOT CONVERTED

NA

NA

n064

DC inj Current

None

b2-02

nj Brkg Current

DC I

n065

DC inj Time @ Stop

n065*10 = b2-04

b2-04

DC INJ Time @Stop

n066

DC inj Time @ Start

n066*10 = b2-03

b2-03

DC INJ Time @ Start

n067

Torq Comp Gain

NOT CONVERTED

NA

NA

n068

Mtr Line to Line Res.

NOT CONVERTED

NA

NA

n069

Mtr Iron Loss

NOT CONVERTED

NA

NA

n070

Stall Prev Decel

None

L3-04

Stall Prevent Sel. During

l

Dece

n071

Stall Prev. Accel Lvl

NOT CONVERTED

NA

NA

n072

NA

Stall Prev Run Lvl

NOT CONVERTED

NA

141

Advertising