Initialize Inverter

Toolbar:

None

Menu:

Inverter >Initialize Inverter

Hot Keys:

None


This function resets the drive to its factory default parameter values. There are 4 settings that
affect which default values are used. When the Initialize Inverter is selected Figure 4.46 will
appear

Figure 4.46: Initialize Inverter Screen

Three of the four properties may be changed to ensure correct initialization. The KVA property
is read only. Once the selections have been chosen, click Initialize to complete the process.
Clicking on cancel stops the operation and closes the window. When Initialize is chosen, the
window in Figure 4.47 appears.

1. When the drive is initialized, all of the drive parameters are reset to their

original factory settings. This could cause machine safety issues if the
drive is not set programmed correctly.

2. You should save all of the drive parameters before performing an

inverter initialization.

3.

The drive initialization function is locked out when you have the Write
Disable function turned on.

L

Important !