This button starts the auto-tune process. It is active only after a load has
been completed. Once clicked, the button will not be active until another
load has been completed.
This button stops the auto-tune process. It is only active while the auto-
tune is running. Once the auto-tune is stopped, you must reload the T1
parameters by clicking on the
Load
before you can start again.
This button cancels the auto-tune process and closes the auto-tune
window. If clicked during auto-tune run, the auto-tune will stop and the
auto-tune window will close.
This spreadsheet shows the appropriate Ex-xx motor parameters in the
drive. The
Before
column data shows the value of the parameters
when the load button is pushed. The
After
column data shows the
value of the parameters after the completed auto-tune. They are read
right after the drive has finished the auto-tune process.
The Auto-tune feature is locked out when the Write Disable function is
turned on.