Hitachi X200 Series User Manual

Page 107

Advertising
background image

“B” Function

Defaults

Func.

Code

Name /

SRW Display

Description

Run

Mode

Edit

-FE

(EU)

-FU

(USA) Units

Selection of automatic restart

mode

B001

IPS POWR

ALM

Select inverter restart method,

Four option codes:
00

…Alarm output after trip, no

automatic restart

01

…Restart at 0Hz

02

…Resume operation after

frequency pull-in

03

…Resume previous freq. after

freq. pull-in, then decelerate

to stop and display trip info

U

00

00

Allowable under-voltage

power failure time

B002

IPS Time

0001.0s

The amount of time a power

input under-voltage can occur

without tripping the power
failure alarm. Range is 0.3 to 25

sec. If under-voltage exists longer

than this time, the inverter trips,
even if the restart mode is

selected.

U

1.0

1.0

sec.

Retry wait time before motor

restart

B003

IPS Wait

0001.0s

Time delay after under-voltage

condition goes away, before the
inverter runs motor again.

Range is 0.3 to 100 seconds.

U

1.0

1.0

sec.

Instantaneous power failure /

under-voltage trip alarm

enable

B004

IPS TRIP

OFF

Two option codes:
00

…Disable

01

…Enable

U

00

00

Number of restarts on power

failure / under-voltage trip

events

B005

IPS RETRY

16

Two option codes:
00

…Restart 16 times

01

…Always restart

U

00

00

Start freq to be used in case
of freq pull-in restart

B011

FSch Md

CUTOFF

Three option codes:
00

…freq at previous shutoff

01

…start from max. Hz

02

…start from set frequency

U

00

00

Deceleration rate of freq pull-

in restart setting

B029

FSch CNS

0000.5s

Sets the deceleration rate when

frequency pull-in restart, range is
0.1 to 3000.0, resolution 0.1

U

0.5

0.5

sec.

Current level of frequency

pull-in restart setting

B030

FSch LVL

002.60A

Sets the current level of

frequency pull-in restart, range is

0.2*inverter rated current to
2.0*inverter rated current,

resolution 0.1

U

Rated

current

A

333

Confi

guri

ng Driv

e

Parameters