C − 6 – Hitachi X200 Series User Manual

Page 272

Advertising
background image

Fine Tuning Functions

“B” Group Parameters

Default Setting

Func.

Code

Name

-FE

(EU)

-FU

(USA)

B031

=10

User

Setting

B001 Selection of automatic restart mode

00

00

9

B002 Allowable under-voltage power failure

time

1.0

1.0

9

B003 Retry wait time before motor restart

1.0

1.0

9

B004 Instantaneous power failure / under-

voltage trip alarm enable

00

00

9

B005 Number of restarts on power failure /

under-voltage trip events

00

00

9

B011 Start freq to be used in case of freq

matching restart

00

00

U

B012 Level of electronic thermal setting

Rated current for

each inverter

9

B212 Level of electronic thermal setting, 2nd

motor

Rated current for

each inverter

9

B013 Electronic thermal characteristic

01

01

9

B213 Electronic thermal characteristic, 2nd

motor

01

01

9

B021 Overload restriction operation mode

01

01

9

B221 Overload restriction operation mode,

2nd motor

01

01

9

B022 Overload restriction level setting

Rated current x 1.5

9

B222 Overload restriction operation mode,

2nd motor

Rated current x 1.5

9

B023 Deceleration rate at overload restriction

1.0

30.0

9

B223 Overload restriction operation mode,

2nd motor

1.0

30.0

9

B028 Source of overload restriction selection

00

00

B228 Source of overload restriction selection,

2nd motor

00

00

9

B029 Deceleration rate of frequency matching

restart setting

0.5

0.5

U

B030 Current level of frequency matching

restart setting

Rated current

U

B031 Software lock mode selection

01

01

9

B050

Selection of the non stop operation

00

00

U

B051

Non stop operation start voltage setting

0.0

0.0

U

B052

OV-LAD Stop level of non stop operation

setting

0.0

0.0

U

B053

Deceleration time of non stop operation

setting

1.0

1.0

U

B054

Frequency width of quick deceleration

setting

0.0

0.0

U

B055

DC bus AVR P-gain

0.2

0.2

U

B056

DC bus AVR I-time

0.2

0.2

U

B057

DC bus AVR D-time

0.0

0.0

U

C6

Appe

ndix C

Advertising