List of Holding Registers

Network Data

Func.

Code

Name

R/W

Description

Reg.

Range

Res.

B052 OV-LAD Stop level of

non stop operation

setting

R/W Setting the OV-LAD stop level of

non stop operation. Range is 0.0

to 1000.0

10CBh 0 to 10000

0.1 V

B053

(high)

R/W

10CCh

B053

(low)

Deceleration time of
non stop operation

setting

R/W

Range is 0.01 to 3000

10CDh

1 to 300000 0.01 sec

B054 Frequency width of

quick deceleration

setting

R/W Setting of the first quick

deceleration width. Range is 0.0

to 10.0

10CEh

0 to 100

0.1 Hz

B055 DC bus AVR P-gain

R/W Proportional gain adjustment for

DC bus AVR function. Range is:

0.2 to 5.0

1173h

2 to 50

0.1

B056 DC bus AVR I-time

R/W Integration time adjustment for

DC bus AVR function. Range is:

0.0 to 150.0

1174h

0 to 1500

0.1s

B080 [AM]analog signal gain R/W Adjust of analog output at

terminal [AM],
range is 0 to 255

10CFh

0 to 255

B082 Start frequency

adjustment

R/W Sets the starting frequency for

the inverter output, range is 0.5

to 9.9 Hz

10D1h

5 to 99

0.1 Hz

B083 Carrier frequency

setting

R/W Sets the PWM carrier (internal

switching frequency), range is

2.0 to 12.0 kHz

10D2h

20 to 120

0.1 Hz

B084 Initialization mode

(parameters or trip

history)

R/W Select the type of initialization to

occur, three option codes:
00

…Trip history clear

01

…Parameter initialization

02

… Trip history clear and

parameter initialization

10D3h

0, 1, 2

B085 Country for

initialization

R/W Select default parameter values

for country on initialization,

three option codes:
00

…Japan

01

…Europe

02

…US

10D4h

B33