“A” Function

Defaults

Func.

Code

Name /

SRW Display

Description

Run

Mode

Edit

-FE

(EU)

-FU

(USA) Units

[AT] selection

A005

AT-Slct

O/VR

Five options; select codes:
02

…Select between [O] and

integrated POT at [AT]

03

…Select between [OI] and

integrated POT at [AT]

04

…Only [O] input active

05

…Only [OI] input active

U

02

02

O-L input active range start

frequency

A011

O-EXS

0000.0Hz

The output frequency

corresponding to the analog input

range starting point,
range is 0.0 to 400.0

U

0.0

0.0

Hz

O-L input active range end
frequency

A012

O-EXE

0000.0Hz

The output frequency
corresponding to the analog input

range ending point,

range is 0.0 to 400.0

U

0.0

0.0

Hz

O-L input active range start
voltage

A013

O-EX%S

00000%

The starting point (offset) for the
active analog input range,

range is 0. to 100.

U

0.

0.

%

O-L input active range end

voltage

A014

O-EX%E

00000%

The ending point (offset) for the

active analog input range,

range is 0. to 100.

U

100.

100.

%

O-L input start frequency
enable

A015

O-LVL

0Hz

Two options; select codes:
00

…Use offset (A011 value)

01

…Use 0Hz

U

01

01

External frequency filter time
constant

A016

F-SAMP

00008

Range n = 1 to 17, where n =
number of samples for avg.

U

8.

8.

Sam-

ples

314

Confi

guri

ng Driv

e

Parameters