Hitachi X200 Series User Manual

Page 172

Advertising
background image

Safety Stop switch condition

Terminal

Number

Default setting

Safety Stop switch

S8 = OFF

Safety Stop switch

S8 =

ON

Safety Stop switch

S8 =

ON Æ OFF

1

FW

FW

FW

2

RV

RV

RV

3

CF1

EMR

[HW based for 1b input]

- (No func.)

4

CF2 [US ver. :USP]

RS

[HW based for 1a input]

RS

[Normal 1a]

5

RS

(PTC assignable)

- (No func.)

- (No func.)

This means that terminal 5 will be “no function” when S8 is made ON. So if you want to

use the terminal 5 with a specific function under the switch S8 is turned ON, you need

to assign manually. Additionally the terminal 3 will also change to no function when the
switch S8 is made OFF again.

Please pay attention not to change the switch S8 needlessly. Otherwise there will be an

unexpected performance of your system.

Option

Code

Terminal

Symbol

Function Name

State

Description

ON

Emergency signal is activated

64

EMR

Safety Stop

OFF Emergency signal is not activated

Valid for inputs:

C001~C005

Required settings

Notes:

• Both active state (normally open or normally

close) setting of EMR and EXT must be the

same setting.

Example (default input configuration shown—see

page 3–49

):

See I/O specs on

page 4–6.

NOTE: In any case the total system (including the inverter unit) must comply to
EN60204-1 (safety of machinery) and other norms that are required. Refer to each norm
that is required on your system.

5

4

3

2

1

L

PCS P24

EMR

RS

433

Operatio

ns and

Monitori

ng