Hitachi X200 Series User Manual

Page 171

Advertising
background image

Safe Stop

The X200 inverter can perform the “uncontrolled stopping by removal of the motor

power” which is Stop Category 0, as defined in EN60204-1.

It is designed and approved suitable for the requirements of Safety Category 3 in

EN954-1, which is a protection against restart, called Safe Stop.

Prior to integration and use of X200 Safe Stop in an installation, a thorough risk
analysis on the installation must be carried out in order to determine whether the X200

Safe Stop functionality and safety category are appropriate and sufficient.

The Safe Stop function of X200 is activated by turning ON the hardware switch (S8)
located on the control card. When the switch S8 is made ON and if the emergency signal

(b-contact) is given to the terminal 3 of the logic terminal block, the inverter removes

the power to the motor only by integrated hardware, not software performance stands
in-between.

Total system comprises an inverter with AC motor and safety-tested external

disconnecting device. The external disconnecting device must have been approved for at
least safety category 3 according to EN954-1.

HIGH VOLTAGE: Dangerous voltage exists even after the Safe Stop is activated. It does

NOT

mean that the main power has been removed.

The X200 inverter complies to EN954-1
category 3. When you turn the switch S8 on

the control card, X200 shuts off the motor

power by hardware.

When the switch S8 is made ON, input terminal for the emergency signal and the

terminal for the reset signal will be assigned automatically to terminal 3 and 4. At this
moment the parameter C003 is changed to EMR and parameter C004 is changed to RS

automatically, and cannot be changed manually. Following table shows the

assignments of each terminal according to the switch S8 condition.

432

Operatio

ns and

Monitori

ng

Switch S8
(Right side)

Isolation

Isolation

Gate

shutoff

circuit

Motor

Emergency
signal

EMR

RS

X200

Reset
signal

Motor

drive IGBT

(Inverter)

Latch

S8