Choosing a Programming Device

Introduction

Hitachi variable frequency drives (inverters) use the latest electronics technology for

getting the right AC waveform to the motor at the right time. The benefits are many,
including energy savings and higher machine output or productivity. The flexibility

required to handle a broad range of applications has required ever more configurable

options and parameters – inverter are now a complex industrial automation component.
And this can make a product seem difficult to use, but the goal of this chapter is to make

this easier for you.

As the powerup test in Chapter 2 demonstrated, you do not have to program very many
parameters to run the motor. In fact, most applications would benefit only from

programming just a few, specific parameters. This chapter will explain the purpose of

each set of parameters, and help you choose the ones that are important to your
application.

If you are developing a new application for the inverter and a motor, finding the right

parameters to change is mostly an exercise in optimization. Therefore, it is okay to
begin running the motor with a loosely tuned system. By making specific, individual

changes and observing their effects, you can achieve a finely tuned system.

Introduction of Inverter Programming

The front panel keypad is the first and best way to get to know the inverter’s
capabilities. Every function or programmable parameter is accessible from the keypad.

The other devices simply imitate the keypad’s layout and inverter access, while adding

another valuable aspect to the system. For example, the Digital Operator/Copy Unit can
transfer one inverter’s parameter settings to another inverter, while still providing

standard operator keypad control. In this way, you can use a variety of programming

devices with basically the same keypad skills. The following table shows various
programming options, the features unique to each device, and the cables required.

Cables (choose one)

Device

Part

Number

Parameter

Access

Parameter

setting

storage

Part number

Length

ICS-1

1 meter

External inverter

keypad

OPE-SRmini

Monitor and

Program

EEPROM in

inverter

ICS-3

3 meters

ICS-1

1 meter

Digital Operator/

Copy Unit

SRW-0EX

Monitor and

Program

EEPROM in

operator panel

ICS-3

3 meters

NOTE: When an external digital operator device such as an OPE-SRmini or SRW-0EX
is connected to the inverter, the inverter’s keypad is automatically disabled (except for
the Stop Key).