Hitachi X200 Series User Manual

Page 7

Advertising
background image

Wiring – Cautions for Electrical Practice

CAUTION: Fasten the screws with the specified fastening torque in the table below.

Check for any loosening of screws. Otherwise, there is the danger of fire.

2-18

CAUTION: Be sure that the input voltage matches the inverter specifications;

• Single phase 200V to 240V 50/60Hz (up to 2.2kW) for SFE model
• Single/Three phase 200V to 240V 50/60Hz (up to 2.2kW) for NFU model
• Three phase 200V to 240V 50/60Hz (3.7kW) for LFU model
• Three phase 380V to 480V 50/60Hz (up to 4kW) for HFx model

2-20

CAUTION: Be sure not to power a three-phase-only inverter with single phase

power. Otherwise, there is the possibility of damage to the inverter and the danger
of fire.

2-20

CAUTION: Be sure not to connect an AC power supply to the output terminals.

Otherwise, there is the possibility of damage to the inverter and the danger of
injury and/or fire.

2-20

vi

Power Input

Output to Motor

X200 Inverter

Advertising