Hitachi X200 Series User Manual
Page 113
Advertising
“B” Function
Defaults
Func.
Code
Name /
SRW Display
Description
Run
Mode
Edit
-FE
(EU)
-FU
(USA) Units
Selection of the non stop
operation
B050
IPS MODE
OFF
Two option codes:
00
…Disabled
01
…Enabled
U
00
00
−
Non stop operation start
voltage setting
B051
IPS V
0000.0V
Setting of DC bus voltage to start
non stop operation. Range is 0.0
to 1000.0
U
0.0
0.0
V
OV-LAD Stop level of non
stop operation setting
B052
IPS OV
0000.0V
Setting the OV-LAD stop level of
non stop operation. Range is 0.0
to 1000.0
U
0.0
0.0
V
Deceleration time of non stop
operation setting
B053
IPS DEC
0001.0s
Range is 0.01 to 3000
U
1.0
1.0
sec
Frequency width of quick
deceleration setting
B054
IPS F
0000.0Hz
Setting of the first quick
deceleration width. Range is 0.0
to 10.0
U
0.0
0.0
Hz
3−39
Confi
guri
ng Driv
e
Parameters
Advertising