B − 29 – Hitachi X200 Series User Manual

Page 256

Advertising
background image

List of Holding Registers

Network Data

Func.

Code

Name

R/W

Description

Reg.

Range

Res.

A092

(high)

R/W

1074h

A092

(low)

Acceleration (2) time

setting

R/W

Duration of 2nd segment of

acceleration, range is:

0.01 to 3000 sec.

1075h

1 to

300000

*1

0.1 sec

A292

(high)

R/W

1519h

A292

(low)

Acceleration (2) time
setting,

2nd motor

R/W

Duration of 2nd segment of
acceleration, 2nd motor, range is:

0.01 to 3000 sec.

151Ah

1 to

300000

*1

0.1 sec

A093

(high)

R/W

1076h

A093

(low)

Deceleration (2) time

setting

R/W

Duration of 2nd segment of

deceleration, range is:
0.01 to 3000 sec.

1077h

1 to

300000

*1

0.1 sec

A293

(high)

R/W

151Bh

A293

(low)

Deceleration (2) time

setting,
2nd motor

R/W

Duration of 2nd segment of

deceleration, 2nd motor, range is:
0.01 to 3000 sec.

151Ch

1 to

300000

*1

0.1 sec

A094 Select method to

switch to Acc2/Dec2

profile

R/W Two options for switching from

1st to 2nd accel/decel:
00

…2CH input from terminal

01

…Transition frequency

1078h

A294 Select method to

switch to Acc2/Dec2

profile, 2nd motor

R/W Two options for switching from

1st to 2nd accel/decel:
00

…2CH input from terminal

01

…Transition frequency

(2nd motor)

151Dh

0, 1

A095 Acc1 to Acc2 frequency

transition point

R/W Output frequency at which

Accel1 switches to Accel2, range
is 0.0 to 400.0 Hz

107Ah

A295 Acc1 to Acc2 frequency

transition point, 2nd

motor

R/W Output frequency at which

Accel1 switches to Accel2, 2nd

motor, range is 0.0 to 400.0 Hz

151Fh

0 to 4000

0.1 Hz

A096 Dec1 to Dec2 frequency

transition point

R/W Output frequency at which

Decel1 switches to Decel2, range

is 0.0 to 400.0 Hz

107Ch

A296 Dec1 to Dec2 frequency

transition point, 2nd

motor

R/W Output frequency at which

Decel1 switches to Decel2, 2nd

motor, range is 0.0 to 400.0 Hz

1521h

0 to 4000

0.1 Hz

A097 Acceleration curve

selection

R/W Set the characteristic curve of

Acc1 and Acc2, two options:
00

…linear

01

…S-curve

107Dh

0, 1

A098 Deceleration curve

selection

R/W Set the characteristic curve of

Dec1 and Dec2, two options:
00

…linear

01

…S-curve

107Eh

0, 1

A101 [OI]-[L] input active

range start frequency

R/W The output frequency

corresponding to the analog

input range starting point,

range is 0.0 to 400.0 Hz

1080h

0 to 4000

0.1 Hz

A102 [OI]-[L] input active

range end frequency

R/W The output frequency

corresponding to the current

input range ending point,
range is 0.0 to 400.0 Hz

1082h

0 to 4000

0.1 Hz

A103 [OI]-[L] input active

range start current

R/W The starting point (offset) for the

current input range,

range is 0. to 100.%

1083h

0 to 100

1 %

B29