4. Configure the following parameters as necessary:

Output ID
An ID number for the log output.

Output Status
Specifies whether or not the output is sent to the syslog server. The
options are:

Enabled - Enables the log output. Event messages are sent to the
defined syslog server.

Disabled - Disables the log output. Event messages are not sent to the
defined syslog server.

Message Format
Specifies the format of the messages sent to the syslog server. The
options are:

Extended - Sends the time, module, severity, description, file name,
line number, and event ID. This is the default.

Normal - Sends the time, module, severity, and description for each
event.

Severity Selections
Specifies the severity of events you want to send to the syslog server.
The possible options are:

ALL - Sends all event messages of the following types. This is the
default.

Error - Sends only error event messages. Error messages indicate that
the switch operation is severely impaired.

Warning - Sends only warning event messages. These messages
indicate that an issue may require manager attention.

Information - Sends only informational event messages. Informational
messages display useful information that you can ignore during normal
operation.

Debug - Sends debug event messages. These events provide detailed
high-volume information that is intended only for technical support
personnel.

Use <Ctrl>+click to select more than one severity at a time.

Type
The only available type is Syslog and you cannot change this.

Syslog Server IP Address
The IP address of the syslog server.