Set switch port – Allied Telesis AT-S63 User Manual

Page 112

Advertising
background image

Chapter 7: Port Parameter Commands

112

SET SWITCH PORT

Syntax

set switch port=

port

[description=

description

]

[status=enabled|disabled]
[speed=autonegotiate|10mhalf|10mfull||100mhalf|100mfull
[mdimode=mdi|mdix] [renegotiation=auto]
[flowcontrol=disable|enable] [fctrllimit=

value

]

[backpressure=yes|no|on|off|true|false|enabled|disabled]
[bplimit=

value

] [holbplimit=

value

]

[bcastfiltering=yes|no|on|off|true|false|enabled|disabled]
[unkmcastfiltering=yes|no|on|off|true|false|enabled|
disabled]
[unkucastfiltering=yes|no|on|off|true|false|enabled|
disabled] [softreset] [priority=

value

]

[overridepriority=yes|no|on|off|true|false]

Parameters

port

Specifies the port you want to configure. You can
specify more than one port at a time, but the ports
must be of the same medium type. For example, you
cannot configure twisted pair and fiber optic ports
with the same command. You can specify the ports
individually (for example, 5,7,22), as a range (for
example, 18-23), or both (for example, 1,5,14-22).

description

A description for the port, from 1 to 15

alphanumeric characters. Spaces are allowed but do
not use special characters.

status

Specifies the operating status of the port. The
options are:

enabled

The port forwards Ethernet frames.
This is the default setting.

disabled

The port does not forward frames.

speed

Sets the speed and duplex mode of the port. The

options are:

autonegotiate The

port autonegotiates both

speed and duplex mode. This is
the default setting.

10mhalf 10

Mbps

and half-duplex mode.

10mfull 10

Mbps

and full-duplex mode.

100mhalf 100

Mbps

and half-duplex mode.

Advertising