Create switch trunk – Allied Telesis AT-S63 User Manual

Page 133

Advertising
background image

AT-S63 Management Software Command Line Interface User’s Guide

133

CREATE SWITCH TRUNK

Syntax

create switch trunk=

name

port=

ports

[select=macsrc|macdest|macboth|ipsrc|ipdest|ipboth]

Parameters

trunk

Specifies the name of the trunk. The name can be up
to 16 alphanumeric characters. No spaces or special
characters are allowed.

port

Specifies the ports to be added to the port trunk. You
can specify the ports individually (for example, 5, 7,
22), as a range (for example, 18-23), or both (for
example, 1, 5, 14-22).

select

Specifies the load distribution method. Options are:

macsrc

Source MAC address.

macdest

Destination MAC address.

macboth

Source address/destination MAC

address.

ipsrc

Source IP address.

ipdest

Destination IP address.

ipboth

Source address/destination IP

address.

Description

This command creates a port trunk. To create the trunk, you specify the
ports on the switch that will constitute the trunk.

Note

All ports in a trunk must operate at the same speed. When you
include port 23R or 24R in a trunk and the port transitions to
redundant uplink status, the port speed is automatically adjusted to
1000 Mbps. If the other ports in the trunk are operating at a different
speed, port trunking may be unpredictable. Because of these port
speed variables, Allied Telesyn suggests that you not include port
23R or 24R in a port trunk.

Advertising