SET SWITCH CONSOLETIMER
Syntax
set switch consoletimer=
value
Parameter
consoletimer
Specifies the console timer in minutes. The range is 1
to 60 minutes. The default is 10 minutes.
Description
This command sets the console timer, which is used by the management
software to end inactive management sessions. If the AT-S63 software
does not detect any activity from a local or remote management station
after the period of time set by the console timer, it automatically ends
the management session. This security feature can prevent
unauthorized individuals from using your management station should
you step away from your system while configuring a switch. To view the
current console timer setting, refer to “SHOW SWITCH” on page 62.
Example
The following command sets the console timer to 25 minutes: