AT-S63 Management Software Command Line Interface User’s Guide

113

100mfull

100 Mbps and full-duplex mode.

Note

A speed of 1000 Mbps is only available when you set the port to
autonegotiate.

Note

When a transceiver is inserted into an uplink slot and a link is
established, that slot becomes a primary uplink port and the
corresponding backup port, 23R or 24R, automatically transitions to
redundant uplink status. The speed and duplex mode of the
redundant port automatically transitions to autonegotiate to match
the speed of the primary uplink port and you cannot configure the
MDI/MDIX crossover parameter.

mdimode

Sets the wiring configuration of the port. This

parameter applies only to twisted pair ports, and
only when a port’s speed and duplex mode are set
manually. If a port is autonegotiating its speed and
duplex mode, the MDI/MDIX setting is established
automatically and cannot be changed. The options
are:

mdi

Sets the port’s configuration to MDI.

mdix

Sets the port’s configuration to MDI-X.

renegotiation

Prompts the port to renegotiate its speed and

duplex mode with the end node. This parameter
only works when the port is using autonegotiation.
The only option is:

auto Renegotiates

speed and duplex mode

with the end node.

flowcontrol

Specifies the flow control on the port. Flow control

applies only to ports operating in full duplex mode.
When flow control is activated, a port sends out a
PAUSE packet whenever it wants the end node to
stop sending packets. The options are:

disabled No

flow

control. This is the default

setting.

enabled

Flow control is activated.