Motion parameters – Rockwell Automation 1746-HSRV SLC Servo Control Module User Manual User Manual

Page 108

Advertising
background image

Publication 1746-6.1.2 - July 2000

Setting Up Your SLC Servo Module 7-29

Motion Parameters

Use the motion parameters in the following table to define your
motion-related specifications (e.g., speed, time to maximum speed)
for the SLC Servo Module.

Excess Following
Error

M0:s.38,39

Value of the following error beyond which an
excess following error fault occurs in position
units.

Output Voltage at +
Max Speed

M0:s.24,25

The voltage at the DAC to command the
Maximum Axis Speed in the positive direction
in volts.

Output Voltage at –
Max Speed

M0:s.26,27

The voltage at the DAC to command the
Maximum Axis Speed in the negative direction
in volts.

Name

Location

Description

Name

Location

Description

Velocity Time Base

M0:s.0/6

Specifies the time base for the speed
parameter specification.

Synchronized Move
Source

M0:s.1/1

Specifies the source for the synchronized move
signal to be either the backplane or the
termination panel.

Maximum Axis Speed M0:s.28,29

Maximum speed for moving an axis in position
units/time unit.

Refer to the

Setting Up Your SLC Servo Module

chapter for more information

.

Time to Maximum
Axis Speed

M0:s.30,31

Maximum time to reach the maximum rated
speed for the axis in seconds.

In-position Band

M0:s.40,41

Specifies a zone around the end point for the
move within which the in-position bit gets set.