Blended configuration – Rockwell Automation 1746-HSRV SLC Servo Control Module User Manual User Manual

Page 187

Advertising
background image

Publication 1746-6.1.2 - July 2000

A-14 Input/Output Quick Reference

Blended Configuration

Use the table below with the Blend Move Output Profile (word 0, bit
14) .

1

s = Slot number for the SLC Servo Module.

Block Command Parameters

Destination M
File Location

1

Format

Possible Values

Default

Blend Move Profile

M0:s.0

BITS

11

XX XXXX XXXX PPPP

0

Number of Blend Points

M0:s.1

USHORT

1 to 32

0

% Acceleration Ramp 1

M0:s.2-s.3

FLOAT

0.0 to 1.0

1.0

Speed 1

M0:s.4-s.5

FLOAT

0.0 to +physical limit

0.0

Absolute Position 1

M0:s.6-s.7

FLOAT

–axis travel limit to +axis travel limit

0.0

% Acceleration Ramp 2

M0:s.8-s.9

FLOAT

0.0 to 1.0

1.0

Speed 2

M0:s.10-s.11

FLOAT

0.0 to +physical limit

0.0

Absolute Position 2

M0:s.12-s.13

FLOAT

–axis travel limit to +axis travel limit

0.0

Reserved
% Acceleration Ramp 32

M0:s.188-s.189

FLOAT

0.0 to 1.0

1.0

Speed 32

M0:s.190-s.191

FLOAT

0.0 to +physical limit

0.0

Absolute Position 32

M0:s.192-s.192

FLOAT

–axis travel limit to +axis travel limit

0.0

Advertising