7-34 Setting Up Your SLC Servo Module

If the current axis position is x, then the following occurs:

The axis moves one revolution of the feedback device in the
direction and at a speed specified by the Home Axis command
(i.e., toward Marker #2 for this example).

Marker #2 is found during the move, but because Final Move to
Marker?
is set to No (0):

The final axis move does not take place.

The current position of the axis is set to the configured Home
Position
+ the distance to Marker #1 (i.e., the marker nearest
the start position) + Home Calibration.

Option 2 Example

When the parameters are set, the axis moves one revolution of the
feedback device in the direction and at the speed that the Home Axis
command specifies when looking for the marker.

The current position of the axis is set to the configured Home Position
+ Home Calibration. If the marker is not found, the problem is reported to
the SLC processor.

Parameters:

Equals:

Final Move to Which Marker?

0

Final Move to Marker?

Yes (1)

If the marker is:

Then:

Found during that one
revolution move

The axis moves at the absolute value of the speed
specified by the configured

Speed/Direction of

Move to the Marker to the marker closest to the start
position.

Not found during that one
revolution move

The problem is reported to the SLC processor

IMPORTANT

To configure and program for a unidirectional axis,
the sign of the speed specified in the Home Axis
command and the direction of the move specified by
the configured Final Move to Marker? must result in
unidirectional axis motion.