background image

Publication 1746-6.1.2 - July 2000

Installing Your SLC Servo Module 4-7

Connecting the Termination
Panel

After mounting the termination panel, connect it to the SLC Servo
Module with the 1746-HCA cable. To connect the termination panel to
the SLC Servo Module:

1. Set the locking latches above and below the connector so the

latch reads OPEN.

2. Open the door of the SLC Servo Module.

3. Hold the connector as shown in Figure 4.5 (left) and insert it

into the D-sub connector on the SLC Servo Module until the
connector is seated.

4. Insert a small, flat-edge screwdriver next to the locking latch

located between the module door and connector.

5. Slide the locking latch to the right with your screwdriver.

6. Insert the small, flat-edge screwdriver next to the locking latch

located between the module door and connector.

7. Slide the locking latch to the left with your screwdriver.

8. Connect the other end of the cable to the 1746-HT termination

panel, as shown in Figure 4.5 (right).