Using the set in-position band command, Typical set offset move data tables – Rockwell Automation 1746-HSRV SLC Servo Control Module User Manual User Manual

Page 150

Advertising
background image

Publication 1746-6.1.2 - July 2000

Programming System Variables 9-7

successfully homed. Set Offset parameters for word 5, bit 4 appear in
the table below.

1

s = Slot number for the SLC Servo Module.

Typical Set Offset Move Data Tables

Before executing a Set Offset move, set Source B for the Equal
instruction in Figure 9.1 to 16. A Set Offset command to set the
position offset to 4.0 is initiated if the float data table is:

And the integer data table is:

Using the Set In-Position Band Command

The Set In-Position Band command sets the online in-position band to
equal the specified value. The units for the in-position band specified
are position units. The in-position band defines a zone around the
end point that defines when the in-position bit is set. Set In-Position
parameters for word 5, bit 8 appear in the table below.

1

s = Slot number for the SLC Servo Module.

This Set In-Position Band command can be issued anytime after the
control is powered up. Refer to the example in Using the Set Axis Gain
Command
.

Block Command Parameters

Location

1

Format

Possible Values

Default

Bit Specifications

O:s.4

Bits

0000 0000 0000 0000

0

Set Offset

O:s.5

Bits

0000 0000 0001 0000

0

Offset

O:s.6-O:s.7

Float

–axis travel limit to
+axis travel limit

0.0

Word

0 (Position)

1

2

3

4

5

F27:0

4.0

Word

0

1

2

3

4

5

N32:0

0

0

0

0

0

16

Block Command Parameters

Location

1

Format

Possible Values

Default

Bit Specifications

O:s.4

Bits

0000 0000 0000 0000

0

Set In-position Band

O:s.5

Bits

XXXX XXX1 0000 0000

0

In-position Band

O:s.6-O:s.7

Float

0.0 to +axis travel limit

0.0