Wiring Without the Termination Panel

Overview

This appendix covers how to wire your SLC Servo Module without a
termination panel and includes the following topics:

Using fast inputs and outputs

Distances to user devices

Wiring your hardware

If you don’t use a termination panel, you must wire from the
connectors on the SLC Servo Module to these user devices:

Fast inputs and outputs

Estop Reset push-button, Estop string, and Estop relay

Power supplies

Encoders

Drives

Using Fast Inputs and
Outputs

When using fast inputs you must snub all inductive and capacitive
loads.

The high-level, on
state output
current:

is:

Maximum
(each output)

+5V @
±20.0 mA

Minimum
(each output)

+0V @
±20.0 mA

ATTENTION

!

To avoid damage to your equipment, do not
overload a 5V fast output circuit by wiring it for 24V.