Input/output quick reference, Appendix, Configuration output bit parameters – Rockwell Automation 1746-HSRV SLC Servo Control Module User Manual User Manual

Page 174: Word 0 parameters

Advertising
background image

1

Publication 1746-6.1.2 - July 2000

Appendix

A

Input/Output Quick Reference

Configuration Output Bit
Parameters

Use the following tables to locate word 0, word 1, word 2 and
multi-word configuration output bit parameters.

Word 0 Parameters

Parameter Name
(Parameter Group)

Destination M

1

FileLocation

Range

Default

Additional Information

DAC Enable
(Servo Loop)

M0:s.0/0

Yes (1) / No (0)

Yes

Move commands are executed but, all motion is
inhibited. This parameter is useful for debuggging
ladder programs when the servo motor is not hooked
up and putting an axis in virtual mode. This lets you
use interpolated, incremental, actual or commanded
positions to generate the master position commands
for the ratioed slave axes in other modules. Use the
SLC Ladder to transfer the position information
between SLC Servo Modules.

Invert DAC
(Servo Loop

M0:s.0/1

Yes (1) / No (0)

No

If the DAC output was positive to make a positive
move, after inversion, the DAC output is now
negative to make a positive move. This parameter is
set up at axis integration time. Refer to the

Setting

Up Your Servo Module chapter in this manual for more
information.

Reverse Feedback
(Servo Loop)

M0:s.0/2

Yes (1) / No (0)

No

If the negative incremental feedback position was
interpreted as negative motion, after the reversal the
negative incremental feedback position is now
interpreted as positive motion. This parameter is set
up at axis integration time. Refer to the

Setting Up

Your Servo Module chapter in this manual for more
information.

Reserved

M0:s.0/3

0

Advertising