Configuring your processor using aps software – Rockwell Automation 1746-HSRV SLC Servo Control Module User Manual User Manual

Page 84

Advertising
background image

Publication 1746-6.1.2 - July 2000

Setting Up Your SLC Servo Module 7-5

7. Press Enter.

8. Press ESC three times to return to the top screen of the Offline

Ladder Editor screen.

9. Press F8 (Display).

10. Press F1 (addr).

11. Enter desired data table address.

12. Press Enter.

13. Enter parameters into Bit (B), Integer (N), or Float (F) files.

14. Press ESC to return to Offline Editor screen.

Configuring Your Processor Using APS Software

Configuring your processor involves assigning the SLC Servo Module
to an open slot in the chassis, setting the file length, and entering
parameters.

To assign your SLC Servo Module to an open slot:

1. Press F4 (OFFLINE CONFIG).

2. Select project file.

3. Press Enter.

4. Press F1 (OFFLINE PRG/DOC).

5. Press F1 (PROCESSOR FUNCTIONS).

6. Press F1 (CHANGE PROCESSOR).

7. Press F5 (CONFIG I/O).

8. Select an open slot.

9. Press F5 (MODIFY SLOT).

IMPORTANT

Use F1 to change the radix between binary and
decimal.