Rockwell Automation 1746-HSRV SLC Servo Control Module User Manual User Manual

Page 85

Advertising
background image

Publication 1746-6.1.2 - July 2000

7-6 Setting Up Your SLC Servo Module

10. Select OTHER. In the Module ID Code area, type 10114. The ID

of the SLC Servo Module automatically creates twelve input
words and twelve output words.

11. Press Enter.

To set the file length and enter parameters:

1. Press F9 (SPIO CONFIG).

2. Press F5 (ADVNCD SETUP).

3. Press F5 and set the M0 file length to 1664 words.

4. Press Enter.

5. Press F6 and set the M1 file length to 1659 words.

6. Press Enter.

7. Press ESC.

8. Press F7 and set the G file size to 0 words.

9. Press Enter.

10. Press ESC.

11. Press F8 (EXIT).

12. Press F8 (SAVE AND EXIT).

13. Press F8 (MONITOR FILE).

14. Press F8 (DATA MONITOR) from the top screen of the Offline

Editor screen to enter parameters into Bit (B), Integer (N), or
Float (F) files.

IMPORTANT

Use F1 to change the radix between binary and
decimal.