7-4 Setting Up Your SLC Servo Module

Configuring Your Processor Using AI-500 Software

Configuring your processor involves assigning the SLC Servo Module
to an open slot in the chassis, setting the file length, and entering the
parameters.

To assign the SLC Servo Module to an open slot:

1. Press F1 (Select Program/SLC-500 Addr).

2. Select project file.

3. Press Enter.

4. Press F2 (Offline Programming/Doc) The Offline Ladder Editor

screen opens.

5. Press F6 (Utility).

6. Press F3 (Type/sr).

7. Select an open slot in the chassis.

8. Press F5 (Select).

9. Select 1746-HSRV Single Axis Motion Controller from the

list.

10. Press Enter.

To set the file length and enter parameters:

1. Press F8 (SPIOCFG).

2. Press F1 and set the M0 file length to 1664 words.

3. Press Enter.

4. Press F2 and set the M1 file length to 1659 words.

5. Press Enter.

6. Press F6 and set the G file size to 0 words.