Homing to a limit switch – Rockwell Automation 1746-HSRV SLC Servo Control Module User Manual User Manual

Page 116

Advertising
background image

Publication 1746-6.1.2 - July 2000

Setting Up Your SLC Servo Module 7-37

If the current axis position is x, the following occurs:

The axis moves one revolution of the feedback device in the
direction and at the speed specified by the Home Axis command (i.e.,
toward Marker #2 for this example) and stops.

Marker #2 is found during the move, and because Final Move to
Marker?
is set to Yes (1), the axis moves at the absolute value of
the speed specified by the configured Speed/Direction of Move to
the Marker
to the nearest marker (i.e., Marker #2 for this
example).

The current position of the axis is set to the configured Home
Position
+ Home Calibration.

Homing to a Limit Switch

The axis moves in the direction and at the speed specified by the
Home Axis command to find the home limit switch first. When the
limit switch is found, the axis moves in the direction and at the speed
specified by the configured Speed/Direction of Move Off the Limit Switch.

The axis position is recorded the moment the axis clears the limit
switch. Subsequently, the axis decelerates and stops.

Other configuration parameters are borrowed for unidirectional
homing.

EXAMPLE

Marker #1 Current PositionMarker #2

– . . . . | . . . . . . . . . . . . . .X . . . .. . . . . . . . . . . . . . . . . . . | . . . . +

If

Move to Marker is set

to:

Then:

No (0)

No further axis motion takes place. Instead, the
current position of the axis is set to the configured
Home Position ± the distance from the limit switch using
the position of the axis recorded earlier +

Home

Calibration.

Yes (1)

The axis moves back to the position of the axis
recorded earlier at the absolute value of the speed
specified by the configured

Speed/Direction of Move

to the Marker.

Advertising