Overview of the SLC Servo Module 1-3

The SLC Servo Module operates in two modes:

Configuration

Command

When operating in the configuration or the command mode, the status
of the module is reported to the SLC processor.

Configuration Mode Operation

You can enter configuration mode only if the system is in Estop. In the
SLC Servo Module, you configure the SLC Servo Module by using M
files containing data provided by the SLC 5/03 (or versions listed
above) processors. All configuration parameters are internal to the SLC
Servo Module and stored in non-battery backed RAM.

In configuration mode, you select the proper setup configuration to
match the servo drive and motor without setting switches and without
special software. If you do not set up your own configuration, the
configuration is set to the default setting.

Command Mode Operation

Motor operations are performed in command mode. To operate in this
mode, set the mode flag (bit 15 in output word 0) to 0. In the
command mode, the SLC processor issues commands and activates
the following operations or moves:

Absolute moves

Incremental moves

Speed moves

Monitor moves

Hold moves

Unhold moves

Blend moves

Emergency stop operations

Homing operations

Preset operations

Clear faults

Alternate home moves