Publication 1746-6.1.2 - July 2000

5-26 Wiring the SLC Servo Module

Figure 5.22 Wiring Diagram for 1394 Systems

TB1

+24

S TR IN G IN

R E S. P B
R E S. P B

R E SE T

ST R ING O U T

Axis Overtravels

(if not directly coupled)

Motor

Thermals

16

17

18

19

TB2

Contactor EN

Contactor EN

DROK

DROK

M1

CR1

CR1

STOP

1
2
3
4
5
6
7
8
9

10

11

12
13
14
15
16

17
18
19
20

DC+

COL

INT

W1

W2

U

V

W

PE

FAULT RESET

ANALOG OUT 1

A0 VREF +
A0 VREF -

SHIELD

SHIELD

SHIELD

SHIELD

A0 ENABLE

A0 TOREF +
A0 TOREF-

A2 VREF +

A2VREF -

A2 TOREF +
A2 TOREF -

A2 ENABLE

ANALOG OUT 2

ANALOG COM

COM

CHASSIS

To ground bar
if not grounded
elsewhere

COMMON

DS1
SOLID GREEN = BUS UP, AXIS ENABLED
FLASHING GREEN = BUS UP, AXIS NOT ENABLED
FLASHING RED/GREEN = READY, BUS NOT UP
FLASHING RED = FAULT
SOLID RED = HARDWARE FAILURE

P1

J26

J27

GND3

DC MINUS BUS

System Module

Servo Input Wiring Board

CONTACTOR ENABLE RELAY

RATED AT 115V AC, 24V DC, 1A INDUCTIVE

DRIVE O.K. RELAY

RATED AT 115V AC, 24V DC, 1A INDUCTIVE

OPTIONAL EXTERNAL SHUNT

USER-SUPPLIED 24V AC RMS OR

24V DC. (NON-POLARIZED)

THREE PHASE INPUT

380 - 460V AC RMS

M1

INPUT FUSING

Estop

24 AC/DC

or

120V AC

50/60 Hz

Drive Enable

Drive

DRIVE

DR RET

SHLD

Important:

This connection is required if the system is grounded

at one end only. We recommend grounding the
system at the drive amplifier only.

Important:

Do not directly connect

Motor Thermals. They
must be isolated with
a relay.