Melsec-q, Point, Remark – MITSUBISHI ELECTRIC QJ71C24N User Manual

Page 117

Advertising
background image

5 - 3 5 - 3

MELSEC-Q

5 DATA COMMUNICATION USING THE MELSEC COMMUNICATION

PROTOCOL

(2) System settings using the GX Configurator-SC

When it is necessary to change the default values registered in the Q series C24,

perform the settings as indicated in Chapter 8 and register these to the flash

ROM in the Q series C24.

• MC protocol system setting

• Transmission control and others system setting

POINT

To write from the external device to the intelligent function module installed in the

MELSECNET/H remote I/O station during communication using the MC protocol,

set the "Write allow/prohibit during PLC CPU RUN" in the GX Developer to enable.

5.1.4 Support of multiple CPU system or redundant system

When the external device accesses a QCPU in a multiple CPU system or redundant

system, it is possible to selectively access either a control or non-control CPU in the

multiple CPU system or a control or standby system CPU or System A or System B

CPU in the redundant system by specifying the target QCPU in "Requested module

I/O No." of the QnA compatible 4C frame for the MC protocol.

Refer to the Reference Manual for details.

Refer to Chapter 2 of this manual for the system configuration.

(Example) When multiple CPU No.1 is specified

F

ram

e I

D

N

o

.

46

H

05

H

S

e

lf

-s

ta

ti

o

n

No

.

Co

m

m

a

n

d

S

u

b

com

m

an

d

D

e

vi

ce c

ode

H

e

ad

de

vi

ce

N

u

m

b

e

r of

dev

ic

e

po

in

ts

S

u

m

c

h

ec

k

co

de

38

H

30

H

33

H

30

H

33

H

45

H

30

H

30

H

30

H

30

H

30

H

30

H

34

H

30

H

31

H

30

H

30

H

30

H

31

H

58

H

2A

H

30

H

30

H

30

H

30

H

34

H

30

H

30

H

30

H

30

H

35

H

H

F

L

8

H

0

L

7

H

0

L

0

H

0

L

0

H

0

L

0

H

0

L

1

H

0

L

1

X

L

0

L

5

PC No

.

0

0

H

0

0

4

H

0

0

0

4

3

0

0

0

E

N

Q

S

tat

io

n N

o

.

30

H

35

H

H

0

L

5

Ne

two

rk

No

.

30

H

37

H

H

0

L

7

E

33

H

36

H

H

3

L

6

R

e

qu

es

te

d

m

o

d

u

le

st

a

ti

o

n N

o

.

R

e

qu

es

te

d

m

o

d

u

le

I/

O

No

.

(Command massage of the QnA compatible 4C frame format 1)

REMARK

• When using the Q series C24 in a multiple CPU system, it is necessary to specify

the QCPU that controls the Q series C24 (hereinafter referred to as the control

PLC) using GX Developer.

• It is also possible to mount a Q series C24 of function version A in a multiple CPU

system. In this case, it is only possible to access the control PLC (PLC No.1).

• It is only possible to access the control PLC if data is communicated by means of

frames other than the QnA compatible 4C frame.

Advertising