(2) List of added setting items for GX Configurator-SC

The following table lists the setting items added to the GX Configurator-SC due to

a software version upgrade.

GX Configurator-SC

Software version

SW0D5C-QSCU-E

Screen

(System

setting/monitor)

Additional setting item

Version

2.06G

Version

2.00A

Version

1.10L

40E,
30D,

20C

10B,

00A

Reference

section

Accumulated count of unlock process normal completion
Accumulated count of unlock process abnormal
completion
Accumulated count of lock process based on circuit
disconnect
Callback permit accumulated count
Callback denial accumulated count
Auto (callback) connection permit accumulated count
Auto (callback) connection denial accumulated count

Modem function
monitor/test

Accumulated count of callback receive procedure cancel
Circuit disconnect wait time (PLC CPU watch use)
Remote password mismatch notification count
designation
Remote password mismatch notification accumulated
count designation
Auto modem initialization designation
Callback function designation
Callback denial notification accumulated count
designation

Modem
function
system
setting

Data No. for callback designation 1 to 10

Section
8.4.4
Section
8.6.2

Transmission
control and other
monitoring/tests

RS-232 control signal status CS (CTS)

RTS (RS) designation
DTR (ER) designation
Transmission control start free area
Transmission control end free area
Send/Recv data monitoring designation
Action for buffer full
Stop by Timer 0 error
Monitor buffer head address
Monitor buffer size

Transmission
control and
other system
settings

Transmission transparent code designation (2nd to 10th)

Section
8.4.5
Section
8.6.3

User frame receive format designation (1st to 4th)
Exclusive format-1 received data count (1st to 4th)

Non procedure
system setting
Non procedure
monitor/test

Timeout at No-protocol

Section
8.4.7
Section
8.6.5

Station. No. (Instruction setting)

Section
8.6.9

Monitor/test others

Communication error clear request for CH and to turn
LED off

Section
8.6.9
Section
8.6.10

Accumulated count of unlock process normal completion
Accumulated count of unlock process normal completion

Auto refresh
setting

Accumulated count of lock process based on circuit
disconnect

Section
4.6

: Setting possible : Setting impossible