3 sequence program for data reception, Melsec-q – MITSUBISHI ELECTRIC QJ71C24N User Manual

Page 131

Advertising
background image

6 - 11 6 - 11

MELSEC-Q

6 DATA COMMUNICATION USING THE NON PROCEDURE PROTOCOL

6.1.3 Sequence program for data reception

This section explains the sequence program for data reception.

For details on the INPUT instruction for data reception, see Chapter 9.

X3 Read request

X4

Abnormal
detection

G.INPUT

Un

D0

D10

M0

M0

M1

M1

Create control data from D0

Processing for normal completion
(receive data is stored)

Processing for abnormal completion
(Reading and discarding received data,
resent request, etc.

(CH1 side)

(CH1 side)

ON during abnormal
reception detection

Q series C24 ready signal

Reception data read request
signal
Reception abnormal detection
signal

INPUT instruction

INPUT instruction complete
device
INPUT instruction complete
device +1
(Normal completion/abnormal completion)

Received data count storage area
(Buffer memory address: 600

H

)

Received data storage area
(Buffer memory address: 601

H

to)

(X1E)

(X3)

(X4)

(M0)

(M1)

1)

2)

3)

4)

4)

INPUT

INPUT

m

n

1

Receive data 1

Receive data 2

Data reception-1

Data reception-2

1 scan

Data reception

2)

3)

ON during abnormal
reception detection

1) Start the self-station PLC.

The values specified with GX Developer are stored in the Q series C24.

2) When the amount of data specified by the received data count or data containing

the receive complete code is received from the external device, the reception data

read request signal turns ON.

3) After the control data for the INPUT instruction is stored in the device, the

sequence program executes the INPUT instruction and reads the receive data.