Melsec-q, Appendix (2) program example, Remark – MITSUBISHI ELECTRIC QJ71C24N User Manual

Page 341

Advertising
background image

App. - 47 App. - 47

MELSEC-Q

APPENDIX

(2) Program example

Changes the initial setting
command into pulses.

Sets the word/byte units
designation to byte.

Transfers the setting value to
the word/byte units designation
area of the buffer memory.

Initial setting command 2

Abnormal completion of REMTO
instruction

Sets 400

H

to the buffer memory head

address for on-demand transmission.

Sets 0

H

to the buffer memory length

for on-demand transmission.

Sets 0C00

H

to the transmission

buffer memory head address.

Sets 400

H

to the transmission buffer

memory length.

Transfers the setting values to the
on-demand function designation
and transmission area designation
areas of the buffer memory.

Initial setting command 3

Abnormal completion of REMTO
instruction

Sets 600

H

to the receive buffer

memory head address.

Sets 200

H

to the receive buffer

memory length.

Transfers the setting value to the
receive area designation area of the
buffer memory.

Initial setting completion

Abnormal completion of REMTO
instruction

<Initial setting command>

<Setting of word/byte units designation>

<Setting of on-demand function designation and transmission area designation>

<Setting of receive area designation>

REMARK

When changing the default values of the following buffer memory areas, refer to

above (2) Program example to perform programming.

• DTR/DSR (ER/DR), DC control designation

• DC1/DC3 (Xon/Xoff) code designation

• DC2/DC4 code designation

• CD terminal check designation (for RS-232)

• Communication system designation (for RS-232)

• Simultaneous transmission priority/non-priority designation

• Retransmission time transmission method designation

• Simultaneously transmission data valid/invalid designation

• No-reception monitoring time (timer 0) designation

Advertising