MELSEC-Q

8 UTILITY PACKAGE (GX Configurator-SC)

8

8.1 Functions Available with Utility Package

The following table lists the utility package function.

( : indicates that the setting is valid with the applicable protocol.)

Function

MC

Non

procedure

protocol

Bidirectional

protocol

Explanation

page

Remarks

Auto refresh setting

Refresh the Q series C24's error codes and set devices on the PLC

CPU side.

Section 4.6

User frame

Register the user frame in the flash ROM.

Section 8.4.1

Data for modem initialization Register the data for modem initialization in the flash ROM.

Section 8.4.2

Data for modem connection

Register the data for model connection in the flash ROM.

Section 8.4.3

Modem function system

setting

Register the system setting values for model function in the flash

ROM.

Section 8.4.4

CHn Transmission

control and others

system setting

Set the transmission specifications with the other device.

(DTR/DSR control, DC code control, communication method, data

communication monitoring timer value, etc.)

Section 8.4.5

CHn MC protocol

system setting

Assign the buffer memory for on-demand function, set the user

frame number, etc.

Section 8.4.6

CHn Non procedure

system setting

Assign the buffer memory needed to perform data communication

using the non procedure protocol, and change the setting values,

etc.

Section 8.4.7

CHn Bidirectional

system setting

Assign the buffer memory needed to perform data communication

using the bidirectional protocol, and change the setting values, etc.

Section 8.4.8

CHn PLC CPU

monitoring system

setting

Set the PLC CPU monitoring function.

Section 8.4.9

System

setting

CHn Transmission

user frame No.

designation system

setting

Set the user frame number to be transmitted, etc.

Section 8.4.10

Can be used

via online

operation.

Can be used

via offline

operation.

System setting default

Reset the setting values in the buffer memory to their default

values.

Section 8.4.11

System setting write

Write the setting values in the buffer memory to the flash ROM.

Section 8.4.11

Flash ROM write

allow/prohibit designation

Set whether to allow or prohibit writing to the flash ROM.

Section 8.4.12

X · Y monitor/test

Perform the monitoring/testing of I/O signals to/from the PLC CPU.

Section 8.6.1

Modem function monitor/test Monitor the execution status of the modem function.

Section 8.6.2

CHn Transmission

control and others

monitor/test

Monitor the status of interface control signals, values set from the

GX Developer, etc.

Section 8.6.3

CHn MC protocol

monitor

Section 8.6.4

CHn Non procedure

monitor/test

Section 8.6.5

CHn Bidirectional

monitor

Monitor the data communication result, I/O signal status, and

setting values in the buffer memory.

Section 8.6.6

CHn PLC CPU

monitoring monitor

Monitor the setting values and operating status of the PLC CPU

monitoring function.

Section 8.6.7

Monitor

CHn User frame

No. designation

monitor for

transmission

Monitor the setting value for user frame to be transmitted.

Section8.6.8

Monitor/test others

Monitor the data reception result, error occurrence status, etc.

Section 8.6.9

ERR LED off

Turn off the ERR LEDs on the front face of the module.

Section 8.6.10

Non procedure protocol

receive data clear

Clear the currently received data.

Section 8.7

Can be used

only via

online

operation.