3 - 28 3 - 28

MELSEC-Q

3 SPECIFICATIONS

Address

Decimal (Hex)

Applicable

protocol

CH1

CH2

Application

Name

Initial
value

MC Non

Bi

Registration

allowed/not

allowed

Reference

section

Cycle time units designation

8256

(2040

H

)

8512

(2140

H

)

0: 100 ms

1: s

2: min

2

Cycle time designation

8257

(2041

H

)

8513

(2141

H

)

0

H

: No designation

1

H

to FFFF

H

: PLC CPU monitoring cycle time

5

H

PLC CPU monitoring function designation

0: Do not use the function.

1: Fixed cycle transmission

8258

(2042

H

)

8514

(2142

H

)

2: Condition agreement transmission

0

PLC CPU monitoring transmission measure designation
(for fixed cycle transmission)

8259

(2043

H

)

8515

(2143

H

)

0: Data transmission (device data and CPU status data)
1: Notification

8260

(2044

H

)

8516

(2144

H

)

Transmission pointer designation (For fixed cycle transmission and
data transmission)

1 to 100: Output head point (send from the nth)

Send the user frames designated in the following transmission

frame No. designation areas from the designated pointer position.
(addresses: CH1 side = BA

H

to 11D

H

, CH2 side = 15A

H

to 1BD

H

)

Output count designation (for fixed cycle transmission and data
transmission)

8261

(2045

H

)

8517

(2145

H

)

1 to 100:Output count (designate the number of frame transmissions.)

Data No. for connection designation (for fixed cycle transmission
and notification)

8262

(2046

H

)

8518

(2146

H

)

For designation
of PLC CPU
monitoring
function

0BB8

H

to 0BD5

H

, 8001

H

to 801F

H

: Data No. for connection

0

R

Allowed

Chapter 2

of User's

Manual

(Application)

8263 to

8268

(2047

H

to

204C

H

)

8519 to

8524

(2147

H

to

2149

H

)

Use prohibited

System area

Number of registered word blocks designation

8269

(204D

H

)

8225

(214D

H

)

0 : No designation
1 to 10: Number of blocks of word devices

Number of registered bit blocks designation

8270

(204E

H

)

8226

(214E

H

)

0 : No designation
1 to 10: Number of blocks of bit devices

It is possible to
designate a
maximum of 10
blocks in total.

PLC CPU abnormal monitoring designation

8271

(204F

H

)

8527

(214F

H

)

0: Do not monitor.

1: Monitor.

Monitoring device designation

8272

(2050

H

)

8528

(2150

H

)

90

H

to CC

H

: Device code

Head device No. designation

8273 to

8274

(2051

H

to

2052

H

)

8529 to

8530

(2151

H

to

2152

H

)

0 or more: Head device No.

Read point designation

8275

(2053

H

)

8531

(2153

H

)

1 or more: Number to read points

Monitoring condition designation (judgment condition
designation)

8276

(2054

H

)

8532

(2154

H

)

1 or more: Monitoring condition

Monitoring condition value designation

8277

(2055

H

)

8533

(2155

H

)

At bit device 0: OFF 1: ON
At word device 0 to FFFF

H

: Monitoring condition value

8278

(2056

H

)

8534

(2156

H

)

Transmission pointer designation (for condition

agreement transmission and data transmission)
1 to 100: Output head point (send from nth)

Send the user frames designated in the following

transmission frame No. designation areas from the
designated pointer position.
(address: CH1 side = BAH to 11DH, CH2 side = 15AH
to 1BDH)

Output count designation (for condition agreement
transmission and data transmission)

8279

(2057

H

)

8535

(2157

H

)

1 to 100: Output count (designate the number
of frame transmissions)

Data No. for connection designation (for condition
agreement transmission and notification)

8280

(2058

H

)

8536

(2158

H

)

For designation
of PLC CPU
monitoring
function

No. 1
block
monitoring
device

0BB8

H

to 0BD5

H

, 8001

H

to 801F

H

: Data No. for

connection

0

R

8281 to

8361

(2059

H

to

20A9

H

)

8537 to

8617

(2159

H

to

21A9

H

)

For designation

of PLC CPU

monitoring

function

Block

monitoring

devices

No. 2 to

10

The structure of each area is the same as the first block monitoring device area

See *2 for the details of each area.

Allowed

Chapter 2

of User's

Manual

(Application)

8362 to

8421

(20AA

H

to

20E5

H

)

8618 to

8677

(21AA

H

to

21E5

H

)

Use prohibited

System area