MELSEC-Q

8 UTILITY PACKAGE (GX Configurator-SC)

[Test Items]

The following accumulated count of times counter values can be cleared to "0" by

the select test function.

Test items

Setting value storage

buffer memory address

Reference section containing

detailed explanation

Accumulated count of unlock process normal completion

22FB

H

Accumulated count of unlock process abnormal completion

22FC

H

Accumulated count of lock process based on circuit disconnection

22FF

H

Callback permit accumulated count

22F0

H

Callback denial accumulated count

22F1

H

Auto (callback) connection permit accumulated count

22F2

H

Auto (callback) connection denial accumulated count

22F3

H

Accumulated count of callback receive procedure cancel

22F4

H

Section 3.3 of

User's Manual (Application)

[Operation procedure]

(Step 1) Display the "Modem function monitor/test" screen.

(Step 2) Click the setting value area of the item to be cleared to "0."

(Step 3) Click the " Execute test ."

The counter value of the selected item becomes "0."