MELSEC-Q

3 SPECIFICATIONS

Address

Decimal (Hex)

Applicable

protocol

CH1

CH2

Application

Name

Initial

value

MC Non

Bi

Registration

allowed/not

allowed

Reference

section

Data registration status for initialization

(for confirmation of registration No.)

0: No registration

1: Registered

551 to 552

(227

H

to 228

H

)

For confirmation

of modem

function

Bit corresponding to registration No. is 0(ON)/1(OFF).

Registration No.9C4

H

(2500) : Address 227

H

(b0) to

Registration No. 9E1

H

(2529) : Address 228

H

(b13)

Number of notification execution

553

(229

H

)

0: Not executed

1 or more: Number of executions

0

R

554

(22A

H

)

Notification execution data No.

0 : Notification not executed
BB8

H

or more: Notification executed

(notification execution No.)

0

R

555 to 557

(22B

H

to 22D

H

)

Data

storage

area 1

System area (use prohibited)

558 to 561

(22E

H

to 231

H

)

Data storage area 2

562 to 565

(232

H

to 235

H

)

Data storage area 3

566 to 569

(236

H

to 239

H

)

Data storage area 4

570 to 573

(23A

H

to 23D

H

)

For confirmation

of notification

status

Data storage area 5

The configuration of each area is the same as the data storage area 1.

Not allowed

Section

8.6.2

Chapter 3

of User's

Manual

(Application)

574 to 590

(23E

H

to 24E

H

)

Use prohibited

System area

591

(24F

H

)

For confirmation
of station No.
setting status
(

3)

Station No. (instruction setting)

Depends

on module

status

R

Not allowed

Section

4.5.2

Section

8.6.3

Section

10.1.6

Communication protocol status (switch setting)

592

(250

H

)

608

(260

H

)

0: GX Developer connection
1: MC protocol (format 1)
2: MC protocol (format 2)
3: MC protocol (format 3)
4: MC protocol (format 4)

5: MC protocol (format 5)
6: Non procedure protocol
7: Bidirectional protocol
8: (For linked operation)

Section

4.5.2

Section

8.6.3

Section

10.1.5

Transmission setting status (switch setting)

Operation setting (b0)
Data bit (b1)
Parity bit (b2)
Odd/even parity (b3)
Stop bit (b4)
Sum check code (b5)
Write during RUN (b6)
Setting modification (b7)

0: Independent
0: 7 bit
0: No
0: Odd
0: 1 bit
0: No
0: Prohibited
0: Prohibited

1: Link
1: 8 bit
1: Yes
1: Even
1: 2 bit
1: Yes
1: Allowed
1: Allowed

593

(251

H

)

609

(261

H

)

Communication rate (b8 to b11)
For system (b12 to b15)

50 bps to 230400 bps
All 0

Communication protocol status (current)

594

(252

H

)

610

(262

H

)

0: GX Developer connection
1: MC protocol (format 1)
2: MC protocol (format 2)
3: MC protocol (format 3)
4: MC protocol (format 4)

5: MC protocol (format 5)
6: Non procedure protocol
7: Bidirectional protocol
8: (For linked operation)

Transmission status (current)

Operation setting (b0)
Data bit (b1)
Parity bit (b2)
Odd/even parity (b3)
Stop bit (b4)
Sum check code (b5)
Write during RUN (b6)
Setting modification (b7)

0: Independent
0: 7 bit
0: No
0: Odd
0: 1 bit
0: No
0: Prohibited
0: Prohibited

1: link
1: 8 bit
1: Yes
1: Even
1: 2 bit
1: Yes
1: Allowed
1: Allowed

595

(253

H

)

611

(263

H

)

For confirmation
of transmission
control status

Communication rate (b8 to b11)
For system (b12 to b15)

50 bps to 230400 bps
All 0

Depends

on

parameter

setting

R

Section

4.5.2

Section

8.6.3

Section

10.1.6

RS-232 control signal status

0: OFF status

1: ON status

RS (b0)
DSR (b1)

DTR (b2)
CD (b3)

CS (b4)
RI (b5)

596

(254

H

)

612

(264

H

)

Control signal
status

Not used (b6 to b15) All 0

Depends

on signal

status

R

Not allowed

Section

8.6.3

Section

10.1.3