Melsec-q, 3 specifications – MITSUBISHI ELECTRIC QJ71C24N User Manual

Page 76

Advertising
background image

3 - 26 3 - 26

MELSEC-Q

3 SPECIFICATIONS

Address

Decimal (Hex)

Applicable

protocol

CH1

CH2

Application

Name

Initial
value

MC Non

Bi

Registration

allowed/not

allowed

Reference

section

7486 to 7526

(1D3E

H

to 1D66

H

)

For registration No. 800F

H

7527 to 7567

(1D67

H

to 1D8F

H

)

For registration No. 8010

H

7568 to 7608

(1D90

H

to 1DB8

H

)

For registration No. 8011

H

7609 to 7649

(1DB9

H

to 1DE1

H

)

For registration No. 8012

H

7650 to 7690

(1DE2

H

to 1E0A

H

)

For registration No. 8013

H

7691 to 7731

(1E0B

H

to 1E33

H

)

For registration No. 8014

H

7732 to 7772

(1E34

H

to 1E5C

H

)

For registration No. 8015

H

7773 to 7813

(1E5D

H

to 1E85

H

)

For registration No. 8016

H

7814 to 7854

(1E86

H

to 1EAE

H

)

For registration No. 8017

H

7855 to 7895

(1EAF

H

to 1DE7

H

)

For registration No. 8018

H

7896 to 7936

(1ED8

H

to 1F00

H

)

For registration No. 8019

H

7937 to 7977

(1F01

H

to 1F29

H

)

For registration No. 801A

H

7978 to 8018

(1F2A

H

to 1F52

H

)

For registration No. 801B

H

8019 to 8059

(1F53

H

to 1F7B

H

)

For registration No. 801C

H

8060 to 8100

(1F7C

H

to 1FA4

H

)

For registration No. 801D

H

8101 to 8141

(1FA5

H

to 1FCD

H

)

For registration No. 801E

H

8142 to 8182

(1FCE

H

to 1FF6

H

)

For registration No. 801F

H

The user registration area has the following combined uses, with

data written by the user according to the purpose of use by the

TO instruction, etc.

See each explanation item concerning the configuration of each

area, the data written, etc.

(1) If data communications is being carried out by user

registration frame.

• User registration frame (User’s Manual (Application),

Chapter 9)

(2) If data communications is being carried out by the modem

function.

• Initialization Data (User’s Manual (Application) Section

3.4.3)

• Connection Data (User’s Manual (Application) Section

3.4.4)

Not allowed

Refer to left

description

8183 to 8191

(1FF7

H

to 1FFF

H

)

Use prohibited

System area

Flash ROM write allow/prohibit designation

8192

(2000

H

)

System

designation

0: Write prohibited

1: Write allowed

0

RW

Not allowed

Section

8.4.12

8193

(2001

H

)

Callback function designation
0

H

: Auto

1

H

: Callback connection (during fixed)·····························(Setting 4)

3

H

: Callback connection (during designated number)·····(Setting 5)

7

H

: Callback connection

(during max. designated number is 10)·····················(Setting 6)

9

H

: Auto/Callback connection (during fixed)·····················(Setting 1)

B

H

: Auto/Callback connection

(during designated number)·······································(Setting 2)

F

H

: Auto/Callback connection

(during max. designated number is 10)·····················(Setting 3)

0

8194

(2002

H

)

For callback

function

Callback denial notification accumulated count designation
0

H

: Not specified

1

H

to FFFF

H

: Notification accumulated number count

1

RW

Allowed

Section

8.4.4

Chapter 3 of

User’s

Manual

(Application)

8195 to 8198

(2003

H

to 2006

H

) Use prohibited

System area

8199

(2007

H

)

Auto modem initialization designation

0: Do not auto initialize 1: Auto initialize

0

Modem initialization time DR (DSR) signal valid/invalid designation

8200

(2008

H

)

0: Do not ignore DR signal.

1: Ignore DR signal.

1

Complete signal handling for modem function designation

8201

(2009

H

)

0: Do not turn on/off X13 to X16.
1: Turn on/off X13 to X16.

1

8202

(200A

H

)

For designation

of modem

function -2

Wait time of notification designation
0000

H

to FFFF

H

: Wait time (unit: s)

10

RW

Allowed

Section

8.4.4

Chapter 3

of User's

Manual

(Application)

8203

(200B

H

)

Use prohibited

System area

8204

(200C

H

)

Remote password mismatch notification count designation

0

H

: No designation

1

H

to FFFF

H

: Notification times

0

8205

(200D

H

)

For remote

password

function

Remote password mismatch notification accumulated count

designation

0

H

: No designation

1

H

to FFFF

H

: Cumulative times of notification

1

RW

Allowed

Section 5.1.5
Section 8.4.4

Chapter 3 of

User's

Manual

(Application)

Advertising