Melsec-q, 10 troubleshooting [displays – MITSUBISHI ELECTRIC QJ71C24N User Manual

Page 254

Advertising
background image

10 - 3 10 - 3

MELSEC-Q

10 TROUBLESHOOTING

[Displays]

1) H/W LED Information Right side (Left side: CH1 information/

Right side: CH2 information)

Displays the transmission status and the communications error status

of the Q series C24.

(Displays 201

H

/202

H

of the buffer memory.)

1/0 1/0 1/0 1/0 1/0 1/0 1/0 1/0

SD WAIT

SIO

PRO.

P/S

NEU.

C/N

NAK

ACK.

For system

Buffer memory address 201

H

b15

b7

b6

b5

b4

b3

b2

b1

b0

to

(Information of CH1 side)

1: Lit/Communication error
0: not lit/No communication error

b8

1/0 1/0

1/0 1/0 1/0

1/0 1/0

1/0

SD WAIT

SIO

PRO.

P/S

NEU.

C/N

NAK

ACK.

For system

Buffer memory address 202

H

b15

b7

b6

b5

b4

b3

b2

b1

b0

to

(Information of CH2 side)

1/0

1/0

b14 b13

b8

CH2 ERR.

CH1 ERR.

2) H/W SW Information Parameter

The switch information of the Q series C24 is displayed.

Numbers 1 through 5 correspond to switches 1 through 5 shown in

Section 4.5.2.

(See Section 4.5.2 of the User's Manual (Basic).)

Advertising